fondo

?Cuáles son las normas de aceptación de puertas cortafuegos de JIAHUI?

?Q: What are the key acceptance criteria for JIAHUI fire doors during installation and final inspection??? ?A:?? JIAHUI fire doors must comply with rigorous national and industry standards to ensure fire integrity, structural stability, and operational reliability. The acceptance process spans three phases: ?pre-installation checks, ?installation execution, and ?post-installation validation. Below are the critical criteria: ?1. Pre-Installation Preparation? ?Dimensional Compliance: Wall opening dimensions must be verified before installation, with tolerances ??≤±5mm? in width/height. Deviations exceeding this require structural correction prior to door fitting. ?Embedded Components: All pre-embedded steel plates (e.g., anchor points) must undergo ?full-penetration welding. Welded joints require complete anti-rust coating (e.g., epoxy primer) to prevent corrosion. ?2. Installation Execution? ?Alignment Precision: Vertical deviation of the door frame: ??≤3mm per meter? (measured with a laser level). Horizontal deviation: ??≤2mm per meter? (checked via precision level). Frame misalignment compromises sealing and must be rectified immediately. ?Gap Management: Clearance between door leaf and frame must be ??≤3mm? on all sides (hinge, lock, top). Gaps exceeding this require adjustment or reseating. All seams must be filled with ?intumescent fire sealant? (e.g., graphite-based strips) to block smoke/flame penetration. ?Closer Calibration: After installation, door closers must enable automatic closure when the door is opened ?**≥90°. Closers failing to reset within ??≤60 seconds**? or exhibiting resistance >80N force are non-compliant. ?3. Final Inspection & Testing? ?Comprehensive Functional Checks: ?Seals: Fire-resistant seals (e.g., ceramic silicone strips) must adhere fully to the frame with ?zero gaps or peeling. ?Hardware: Hinges, locks, and closers must operate smoothly without jamming, deformation, or excessive force (>80N). Apariencia: Las superficies deben estar libres de abolladuras, óxido o defectos de recubrimiento (según GB 12955-2008). Validación de rendimiento de terceros: Las puertas muestreadas por lotes (mínimo 1 por cada 50 unidades) deben someterse a pruebas de laboratorio independientes según GB/T 7633 o ISO 834, que incluyen: Resistencia al fuego: Mantener la integridad estructural y el aislamiento durante la duración nominal (p. ej., 90 min para Grado A). Fuga de humo: Fuga de aire ≤1,5 ??m3/(m·h) a una presión diferencial de 50 Pa. Los informes de las pruebas deben presentarse antes de la aprobación del proyecto. Documentación y cumplimiento Registros obligatorios: Certificaciones de fábrica (aprobación ISO/FM), informes de pruebas de productos y registros de instalación. Certificados de inspección de terceros para耐火性能 (resistencia al fuego) y气密性 (hermeticidad). Manejo de No Conformidades: Las puertas que no cumplen con algún punto de control requieren una solución (por ejemplo, resellado, reemplazo de herrajes) y una nueva inspección. Las fallas persistentes provocan el rechazo del lote.
Obtenga el último precio? Le responderemos lo antes posible (dentro de las 12 horas)
This field is required
This field is required
Required and valid email address
This field is required
This field is required
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.